Methanol Alcohol
0,00 €Methanol, also known as methyl alcohol amongst other names, is a chemical and the simplest alcohol, with the formula CH₃OH. It is a light, volatile, colourless, flammable liquid with a distinctive alcoholic odour similar to that of ethanol.
VEM Gas Engine Oil
0,00 €USES
Gas engines have very well defined lubricant needs . Most OEMS specify narrow bands of sulphated ash, which is required to optimize performance for particular engine. Behran gas engine Oils are lubuecants with additional properties which help in maintaining performance at varying temperatures range of gas engines, and have been developed to deliver optimum value to equipment operation through enhanced wear protection, long oil life and high system efficiency that to meet the challenges of a wide range of gas engines and applications.
- BEHRAN GAS ENGINE OIL VEM is superior quality medium ash for automotive gas engines in trucks or buses, meets API CF-4All of kind Behran Gas Engine Oils are available in SAE grades 40& 15w-40
GL-5 Gear Oil Manual
0,00 €USES
- Gear Oil GL -5 is heavy duty extreme pressure (EP) lubricant which is used for lubrication of gears exposed to high temperatures and heavy loads and is also recommended for hypoid transmission and gear boxes.
Phase Capacitor Run Electro Motors
0,00 €Dimension (Foot mounting – Flange mounting)
| Frame No.IEC | T | S | P | N | M | LA | AK | HD | H | C | B | BA | K | KB | AB | A | AA | HA | AC | Z | Q | I | L | E | EH | DH | GA | LK | F | D | FLANGE SYS.IEC 72-1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 56 | 3 | 7 | 120 | 80 | 100 | 8 | 105 | 145 | 56 | 36 | 71 | 19 | 6 | 10 | 112 | 90 | 22 | 10 | 106 | 76 | 55.5 | – | 189 | 20 | – | – | 10.2 | 12 | 3 | 9 | FF100 |
| 63 | 3 | 10 | 140 | 95 | 115 | 10 | 106 | 158 | 63 | 40 | 80 | 25 | 7 | 10 | 125 | 100 | 25 | 10 | 123 | 76 | 54.5 | – | 214 | 23 | – | – | 12.5 | 12 | 4 | 11 | FF115 |
| 71 | 3.5 | 10 | 160 | 110 | 130 | 10 | 110 | 175 | 71 | 45 | 90 | 18 | 7 | 10 | 140 | 112 | 28 | 11 | 138 | 76 | 58 | – | 241 | 30 | – | – | 16 | 18 | 5 | 14 | FF130 |
| 80 | 3.5 | 12 | 200 | 130 | 165 | 12 | 130 | 194 | 80 | 50 | 100 | 25 | 10 | 14 | 160 | 125 | 35 | 11 | 156 | 96 | 68.5 | – | 276 | 40 | – | – | 21.5 | 25 | 6 | 19 | FF165 |
| 90L | 3.5 | 12 | 200 | 130 | 165 | 12 | 137 | 215 | 90 | 56 | 125 | 30 | 10 | 14 | 182 | 140 | 43.3 | 12 | 175 | 96 | 70.5 | – | 325 | 50 | 19 | M8 | 27 | 32 | 8 | 24 | FF165 |
| 100L | 4 | 15 | 250 | 180 | 215 | 12 | 145 | 233 | 100 | 63 | 140 | 35 | 12 | 17 | 200 | 160 | 40 | 12 | 194 | 96 | 73.5 | – | 366 | 60 | 22 | M10 | 31 | 40 | 8 | 28 | FF215 |
| 112M | 4 | 15 | 250 | 180 | 215 | 12 | 155 | 256 | 112 | 70 | 140 | 35 | 12 | 17 | 235 | 190 | 45 | 13 | 217 | 96 | 76.5 | 200 | 384 | 60 | 22 | M10 | 31 | 40 | 8 | 28 | FF215 |

PARS YAKHSAR Anti freeze
0,00 €PARS YAKHSAR is an organic Anti-Freeze, Anti-Boil and Anti –Rust with premium performance, based on monoethylene glycol and powerful organic corrosion inhibitor for use in all automotive cooling systems. It is boron, nitrite, phosphate, silicates and Amine free.
Applications
- Passenger car engines and light duty diesel engines cooling system
Performance Features
- Excellent protection for all cooling system parts against corrosion and rust
- Raises the boiling point
- Excellent chemical stability
Performance Levels
- BS 6580
- ISIRI 338
Three Phase Electro Motors With Energy Grade Of IE2
0,00 €Dimension (Foot mounting)
| Frame No.IEC | HD | H | C | B | BA | K | KB | AB | A | AA | Z | HA | AC | Q | I | L | E | EH | DH | GA | LK | F | D |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 80 | 194 | 80 | 50 | 100 | 25 | 10 | 14 | 160 | 125 | 35 | 96 | 11 | 156 | 68.5 | – | 276 | 40 | – | – | 21.5 | 25 | 6 | 19 |
| 90L | 215 | 90 | 56 | 125 | 30 | 10 | 14 | 182 | 140 | 43.3 | 96 | 12 | 175 | 70.5 | – | 325 | 50 | 19 | M8 | 27 | 32 | 8 | 24 |
| 100L | 233 | 100 | 63 | 140 | 35 | 12 | 17 | 200 | 160 | 40 | 96 | 12 | 194 | 73.5 | – | 366 | 60 | 22 | M10 | 31 | 40 | 8 | 28 |
| 112M | 256 | 112 | 70 | 140 | 35 | 12 | 17 | 235 | 190 | 45 | 96 | 13 | 217 | 76.5 | 200 | 384 | 60 | 22 | M10 | 31 | 40 | 8 | 28 |
| 132M | 291 | 132 | 89 | 178 | 40 | 12 | 17 | 260 | 216 | 44 | 116 | 14 | 255 | 90 | 258 | 486 | 80 | 28 | M12 | 41 | 56 | 10 | 38 |
| 160L | 340 | 160 | 108 | 254 | 50 | 15 | 21 | 315 | 254 | 64 | 116 | 16 | 303 | 95.5 | 345 | 629 | 110 | 36 | M16 | 45 | 80 | 12 | 42 |

QG-125 Jet Heater
0,00 €The Jet Heater Model QG-125, with thermal capacity of 100.000 kcal/h is designed to install and operate on industrial and semi-industrial halls workshops in which they have natural air flow ventilation. The thermal efficiency of the present device is extremely high and its fuel consumption is adjusted with the electrical valve.
The Jet heater QG-125 equipped with low-noise axial fans and Self-regulating system for controlling the gas flow to prevent incomplete combustion. The present device operates on Natural Gas (NG) and liquefied petroleum gas (LPG) and the heating space is 1500 – 5000 m3.
QG-25 Jet Heater
0,00 €The Jet Heater Model QG-25 is designed to operate on Natural Gas (NG) and liquefied petroleum gas (LPG) in order to use in an industrial and workshop. Portable as the capabilities of the present model, which allows the heater to move and operate under any circumstance. Reduction of electricity and fuel consumption and Lightweight are an important feature of this product. A major application of the present product is in Stretch ceiling, which, due to the Lightweight of the system, and can be changed the direct heat in any position and angle.
KHG-100 Vertical Warm Air Furnace
0,00 €The Warm Air Furnace KHG-100 is designed in three models such as Natural Gas, Gasoline and Dual for large heating space including Sport Halls, industrial halls, and public and etc. The thermal capacity of is 100.000 kcal/h it provides heating space up to 1000 – 2500 m3. The hot Air Furnace KHG-100 is a heating system that through the electro fan installed next to the heat exchanger , after vacuum the cooling air from environment and passes cool air through heat exchanger , it causes heat exchanger passed through a heat surface to the environment either directly or through the channeling system. The heat exchanger brings the heat directly by the flame. The unit controls heating automatically and provide a benefit such as intelligent control and safety of fuel and oxygen in compare with past heating system. These forced Air Furnace operate with no open flame and no danger of carbon monoxide poisoning due to complete combustion.
Exhaust gas is emitted as a result of the combustion of fuels is controlled. The heat exchanger is connected to chimney through the tube in order to release of combustion gases. These units in a large model can be connected to the particular channel in order to heat transfer.
KHG-200 Vertical Warm Air Furnace
0,00 €The Warm Air Furnace KHG-200 is designed in three models such as Natural Gas, Gasoline and Dual for large heating space including Sport Halls, industrial halls, and public and etc. The thermal capacity of is 200.000 kcal/h it provides heating space up to 2000 – 5000 m3.
The hot Air Furnace KHG-200 is a heating system that through the electro fan installed next to the heat exchanger , after vacuum the cooling air from environment and passes cool air through heat exchanger , it causes heat exchanger passed through a heat surface to the environment either directly or through the channeling system. The heat exchanger brings the heat directly by the flame.
Capacitor Run Two-Speed Evaporative Cooler Electro Motors
0,00 €Product Specification
| Type | Frame size | Output Power | Output Power | Rated Voltage | Speed in rated load | Rated Current | Rated Torque | Power factor | Starting / Rated Current | Starting / Rated Torque | Break down / Rated Torque | Capacitor Run | Capacitor Run | Poles |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CR 56-4/6-Col | 56 | 0.187/0.062 | 1/4 / 1/12 | 220 | 1425/950 | 1.58/0.7 | 1.25/0.62 | 0.97/0.95 | 3.1 | 1.17 | 2.1/2.25 | 10/8 | 400/400 | 1 |
| CR 56-4/6-D01 | 56 | 0.25/0.7 | 1/3 / 1/10 | 220 | 1425/950 | 2.3/1 | 2.1/0.98 | 0.96/0.98 | 3.69 | 1.14 | 1.85/0.97 | 16/8 | 400/400 | 1 |
| CR 56-4/6-E01 | 56 | 0.37/.0124 | 1/2 / 1/6 | 220 | 1425/950 | 3.5/1.3 | 3.2/1.25 | 0.94/0.93 | 3.65 | 0.88 | 1.61/1.76 | 20/12.5 | 400/400 | 1 |
| CR 56-4/6-F01 | 56 | 0.55/0.18 | 3/4 / 1/4 | 220 | 1425/950 | 3.75/1.69 | 3.75/1.87 | 0.99/0.97 | 3.6 | 0.56 | 1.73/1.25 | 25/12.5 | 400/400 | 1 |
Burner Electro Motors
0,00 €Product Specification
| Type | Output Power | Rated Voltage | Speed in rated load | Rated Current | Efficiency (%) | Power factor | Starting / Rated Current | Starting / Rated Torque | Break down / Rated Torque | Capacitor Run | Capacitor Run | Poles |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| EB90-21A | 0.06 | 220 | 2690 | 0.55 | 52 | − | 2.3 | 0.8 | 1.6 | 4 | 400 | 1 |
| EB90-21B | 0.09 | 220 | 2800 | 0.75 | 57 | 0.96 | 2.8 | 0.82 | 2 | 5 | 400 | 1 |
| EB90-21C | 0.11 | 220 | 2700 | 0.85 | 60 | − | 2.4 | 0.65 | 1.4 | 6.3 | 400 | 1 |
| EB90-21D | 0.125 | 220 | 2730 | 1.01 | 56 | 1 | 2.64 | 0.82 | 1.67 | 6.3 | 400 | 1 |
| EB90-21E | 0.15 | 220 | 2710 | 1.15 | 61 | − | 2.8 | 0.63 | 1.6 | 6.3 | 400 | 1 |
| EB90-21F | 0.18 | 220 | 2700 | 1.25 | 67 | − | 3 | 0.43 | 1.4 | 6.3 | 400 | 1 |
| EB90-21G | 0.24 | 220 | 2700 | 1.7 | 66 | 0.97 | 3 | 0.35 | 1.44 | 8 | 400 | 1 |