QG-95 Jet Heater
0,00 €The Jet Heater Model QG-95 is designed to install and operate on industrial and semi-industrial halls workshops in which they have natural air flow ventilation. The thermal efficiency of the present device is extremely high and its fuel consumption is adjusted with the electrical valve.
The Jet heater QG-95 equipped with low-noise axial fans and Self-regulating system for controlling the gas flow to prevent incomplete combustion. It’s operates on Natural Gas (NG) and liquefied petroleum gas (LPG) and the heating space is 1000 – 3000 m3.
QG-65 Jet Heater
0,00 €The Jet Heater Model QG-65 is designed to install and operate on industrial and semi-industrial halls workshops in which they have natural air flow ventilation. The thermal efficiency of the present device is extremely high and its fuel consumption is adjusted with the electrical valve.
The Jet heater QG-65 equipped with low-noise axial fans and Self-regulating system for controlling the gas flow to prevent incomplete combustion. It’s operates on Natural Gas (NG) and liquefied petroleum gas (LPG) and the heating space is 400 – 2500 m3.
Circulator pump Split-phase electromotors
0,00 €Product Specification
| Type | Frame size | Output Power | Output Power | Rated Voltage | Speed in rated load | Rated Current | Rated Torque | Power factor | Starting / Rated Current | Starting / Rated Torque | Break down / Rated Torque | Inertia moment | Poles |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SP 56-4A | 56 | 0.124 | 1/6 | 220 | 1425 | 2 | 0.83 | 0.612 | 6.35 | 1.9 | 2.38 | 0.001581 | 1 |
| SP 56-4 | 56 | 0.25 | 1/3 | 220 | 1425 | 2.5 | 1.67 | 0.781 | 10.8 | 2.48 | 1.87 | 0.002488 | 1 |
| SP56-4B | 56 | 0.124 | 1/6 | 220 | 1425 | 1.4 | 0.83 | 0.754 | 8.26 | 1.96 | 2.1 | 0.002034 | 1 |
| SP 56-4/6 | 56 | 0.25/0.07 | 1/3 / 1/10 | 220 | 1425/950 | 2.5/1.6 | 1.67/0.75 | 0.781/0.565 | 9.1 | 2 | 1.83/2.67 | 0.002488 | 1 |

2EDB-70 Jet Heater
0,00 €The Jet Heater Model 2EDB-70 is equipped with Chimney as well as capability of double engine. The unit run on gas and diesel fuel at the same time according to its application and equipped with thermal sensor and flow switch that prevent to temperature rise of 140 degree Celsius (Overheat safety shut-off) and ensure the unit safety. The heater providing the desired warmth and comfort for Greenhouses and industrial due to bring fresh air from outside and exhaust polluting gases through chimney. The existence of 100-liter fuel tank of the unit provides the user to use the operation as a portable. Thermal capacity is 70.000 kcal/h, the quantity of the air flow is 5000 m3 and provide heating space up to 700 – 2000 m3.
HA-300 Horizontal Warm Air Furnace
0,00 €The Warm Air Furnace HA-300 is a series of air Furnace that designed horizontally (cabins). This series is suitable for greenhouses due to its low height in compare with Vertical one. It’s designed in three models such as Natural Gas, Gasoline and Dual and generated as axial fan and centrifuge according to the order. The thermal capacity is 300.000 kcal/h and it provides heating space up to 2500 – 7500 m3.
The forced Air Furnace HA-300 is a heating system that through the electro fan installed next to the heat exchanger , after vacuum the cooling air from environment and passes cool air through heat exchanger , it causes heat exchanger passed through a heat surface to the environment either directly or through the channeling system.
HA-200 Horizontal Warm Air Furnace
0,00 €The Warm Air Furnace HA-200 is a series of air Furnace that designed horizontally (cabins). This series is suitable for greenhouses due to its low height in compare with Vertical one. It’s designed in three models such as Natural Gas, Gasoline and Dual and generated as axial fan and centrifuge according to the order. The thermal capacity is 200.000 kcal/h and it provides heating space up to 2500 – 5000 m3.
The forced Air Furnace HA-200 is a heating system that through the electro fan installed next to the heat exchanger , after vacuum the cooling air from environment and passes cool air through heat exchanger , it causes heat exchanger passed through a heat surface to the environment either directly or through the channeling system. The heat exchanger brings the heat directly by the flame. The unit controls heating automatically and provide a benefit such as intelligent control and safety of fuel and oxygen in compare with past heating system. These forced Air Furnace operate with no open flame and no danger of carbon monoxide poisoning due to complete combustion.
KHG-300 Vertical Warm Air Furnace
0,00 €The Warm Air Furnace KHG-300 is designed in three models such as Natural Gas, Gasoline and Dual for large heating space including Sport Halls, industrial halls, and public and etc. The thermal capacity of is 300.000 kcal/h it provides heating space up to 3000 – 7000 m3.
The hot Air Furnace KHG-300 is a heating system that through the electro fan installed next to the heat exchanger , after vacuum the cooling air from environment and passes cool air through heat exchanger , it causes heat exchanger passed through a heat surface to the environment either directly or through the channeling system. The heat exchanger brings the heat directly by the flame. The unit controls heating automatically and provide a benefit such as intelligent control and safety of fuel and oxygen in compare with past heating system.
Air Inlet
0,00 €These types of ducts are located on the upper side of the wall to allow air to be combined with the air in the upper part of the hall. In cold weather, the cold air blends out of the inside with warm air, thus saving fuel and maintaining the desired temperature. The proper airflow is possible when the inlet valves are opened and closed properly.
Portland Cement Type 1-325
0,00 €Portland cement Type 1-325 Application
It is useable in all Reinforced concrete and Non Reinforced concrete and basically all the cases that need special specs like resistance towards striking Ions and hydration heat are not considered. Because of high primary and final resistance especially in cases that need for faster opening and transferring of formwork of concrete is proposed it is used in building concrete silos as well. Also because of high amount of Phase C3S and as a result of produced heat the cement can be used in winter mild climate and thanks to this , this kind of cement is used cautiously in hot areas where the danger of increasing concrete temperature exists.
Shrink Packing Machine SH – R12 Packaging Machine
0,00 €wrapping of Different kind of bottle with tray for products like , tomato paste , beer , Yogurt , pickles.
Portland Cement Type 1-525
0,00 €Portland Cement Type 1-525 Application
| Row | Type of Cement | Type of Test | Forced limits matching Iran Standard under No. ISIRI389 | Delijan Cement Specs |
| 3 | Portland Cement Type 1-525 | 2 day Compressive Strength | Min 200 kg/ cm2 | 220 +_ 10 kg/ cm2 |
| 28 day Compressive Strength | Min 525 kg/ cm2 | 560 +_ 10 kg/ cm2 |
Labeling Machine OPP – LB 330
0,00 €For labeling round shape plastic containers (PET, polyethylene…), metal cans, and glass containers.