Hard Drawn Copper

0,00 

The above wires consist of several twisted copper wires that are without sheath (bare).
These wires do not have annealing properties, which makes them stronger than soft drawn (annealed) copper wires.

Heat Exchanger

0,00 

Introduction

Heat exchangers as an air-to-air cooling system are designed for reliable and energy-efficient temperature control in telecomunications cabinets. These passive cooling systems (close loop systems) are perfectly fit for maintaining an internal temperature between  5°C  and  15°C  above  ambient temperature that are suitable for mountainous regions.

Heavy Slurry pump (ISO 5199)

0,00 

Usages:

  • Steel complex and mining

Design:

Horizontal, radially split volute casing pump in back pull-out design, with impeller adapted to meet application requirements, single-flow, and single-stage.

Special Features:
  • Reinforced, axially adjustable bearing assembly on all pumps.
  • Shaft seal: mechanical seal integrated into the casing cover, or gland packing.
  • Even cast iron pumps are supplied with pump internals (impeller and wear plate) made of wear-resistant ERN (nickel cast iron).

High frequency Coaxial Cable (50,75 ohm)

0,00 

Cable structure:

  • Cu / PE / Cu / PVC
  • Plain annealed single or stranded copper conductor
  • PE insulation
  • Braided copper shield
  • PVC sheath , white or gray

High Intensity Runway/Taxiway Light (AC/DC)

Telecom and Communication Towers
Road and Urban Warning Signs
Buildings and Tall Towers
PWM Modulation Circuit
High Bright Energy Saving LEDs

Store:  A.S.D Co
0 out of 5

High Pressure Pump (ISO 5199)

0,00 

Usages:

  • Fire Fighting
  • Water

Product features

  • Horizontal or vertical, long or close-coupled,
  • multistage centrifugal pump in ring-section design,
  • with axial or radial suction nozzle, cast radial impellers.

HIS 8DQ1 GIS High Voltage Switchgear High Voltage

0,00 

The 8DQ1-type HIS is a compact switchgear solution for rated voltages of up to 550 kV. It is used mainly for cost-efficient renewal or expansion of air-insulated outdoor and indoor substations, particularly if the operator wants to carry out modifications while the switchgear is in service.

Instrument cables – Armoured Single Core

0,00 

Armoured Single Core, 0.6/1 kV, 1x2x2.5 RM SQMM, Oil RESISTANT

Instrument cables- Armoured Multi Core – Oil Resistant

0,00 

Armoured Multi Core, 300/500 V, 19x2x0.5+0.5 RM SQMM, Oil Resistant

Instrumentation Cables

0,00 

Instrument cables are cables that are responsible for transmitting signals and data. These cables are designed to be resistant to electromagnetic interference and noise.
The latest standard used to manufacture and test instrument cables as well as control cables is BS EN 50288-7, but a wide range of applicants still use older standards such as BS 5308.
The type of wire placement in Instrument cables is multi-core, pair, triple and quad. Each of the handles may be placed inside a sheath (Individual Screen) and then twisted together, and the overall set of twisted strands is placed inside the final shield (overall screen).
In the structure of instrument cables, the conductor type is generally type 2 or flexible, but according to customers’ requests, it is possible to produce with other classes such as core (class 1) or flexible (class 5). Copper conductor material can also be used as plain copper or tin-coated.

Instrumention Cables

0,00 

Instrument cables are cables that are responsible for transmitting signals and data. These cables are designed to be resistant to electromagnetic interference and noise.